Projects in our workshop or/and on site

Complete overhaul of Howden WRV204 for replacement on site of MK2/WRV204 compressor

Location: workshop

—–

Complete overhaul of Howden WRV163 on site

Location: Norway

—–

Complete overhaul Howden XRV163

Location: workshop

—–

Complete overhaul of SAB163

Location: workshop

—–

Bearing exchange and capacity inspection on a Howden MK5/WRV255/220

Location: LWM for Equans

—–

In France we overhauled a Howden MK6/WRVi255/220 on site, oil has been changed aswell the coalescer elements.

 

Locatio: Mesnil St. Nicaise for Lebrun Cooling

—–

Complete overhaul of 2 off Howden MK5/WRV255/130 after +111.000 hours. Also oil and coalescer filters have been replaced.

  

  

Location: Eurofrigo Maasvlakte Coldstores.

—–

Oil pumps changed on 2 off Howden WRV204 high stage compressor units. Old pumps David Brown are removed and replaced by Leistritz Flexcore 045/090 pumps. In meantime we inspected 1 off the high stages and 1 off the low stage compressors.

  

Location: Linde Gas, Germany

—–

Complete overhaul of a Howden screw compressor MK4/WRV204/16526 and a David Brown oil pump, from an ice cream factory in Belgium.

Location: workshop Beltman Compressor Techniek BV

—–

Complete overhaul of a Howden screw compressor MK6/WRV204/11026 for a gas facility in Rostock, Germany.

Location: workshop Beltman Compressor Techniek BV

—–

Complete overhaul of a Gram screwcompressor GSV263 with restored slide valve supports. These supports were worn and restored again by using laser cladding and milling.

Assignment for Belgian Icecream Group Tielen

  

Location: workshop Beltman Compressor Techniek BV

—–

Complete overhaul of a Howden screw compressor MK5/WRV204/14526 and a Viking pump, from a slaughterhouse in Germany.

Assignment for Zimmermann Kältetechnik

  

Location: workshop Beltman Compressor Techniek BV

—–

Complete overhaul of a Howden screwcompressor WRV321. All gaskets, seals, bearings have been replaced, also the runway of the slide valve has been restored.

Location: Workshop Beltman Compressor Techniek BV

—–

Inspections and thrust bearing replacements of 2 off Howden WRV321 and 1 off WRV255 on site.

Location: French Fries factory in The Netherlands

—–

Complete overhaul of a Howden screwcompressor WRV365, all seals, gaskets and bearings replaced.


Location: Jordan

—–

Complete overhaul of a Howden screw compressor MK4/XRV163.

Assignment for Belgian refrigeration company Lebrun Nimy.

Location: Beltman Compressor Techniek workshop

—–

Complete overhaul of a GRAM GSV185 screw compressor. The discharge cover and rotors are restore after severe bearing damage.

Assignment for a Belgian ice cream company.

Location: Beltman Compressor Techniek workshop

—–

Complete overhaul of a Howden screw compressor MK4/WRV204/16526 and a David Brown oil pump, from an ice cream factory in Belgium.

Location: Beltman Compressor Techniek workshop

—–

Complete overhaul of a Howden screw compressor MK5/WRV204/14526 and a Viking pump, from a slaughterhouse in Germany. This compressor is provided with an oversized slide valve, after severe wear of the slide valve bore. This oversized slide valve is produced at our own facility.

Assignment for Zimmermann Kältetechnik

 

Location: Beltman Compressor Techniek workshop

—–

Complete overhaul of a Howden screw compressor MK5/WRV204/16536 from a fries factory in The Netherlands. This compressor is provided with an oversized slide valve, after severe wear of the slide valve bore. This oversized slide valve is produced at our own facility.

Assignment for Engie Netherlands.

 

Location: Beltman Compressor Techniek workshop

—–

Complete overhaul of a Howden screw compressor MK5/WRV204/11036, to be installed at a poultry factory in The Netherlands.

Location: Beltman Compressor Techniek workshop

—–

Complete overhaul of a Howden screw compressor MK6/WRV204/19326 and a Viking oil pump.

Compressor overhauled for Engie Netherlands.

Location: Beltman Compressor Techniek workshop

—–

Complete overhaul of a Howden screw compressor MK5/WRVTS321/132. This is a cast steel compressor provided with new tilting pad bearings.

Location: Beltman Compressor Techniek workshop


Complete overhaul of 3 off Howden screw compressors MK6/WRV204/19326. the compressors are used in an AC plant in Germany.

Assignment for GEA Germany.

Location: Beltman Compressor Techniek workshop

—–

Complete overhaul of a GRAM GSV185 screw compressor. The discharge cover and rotors are restore after severe bearing damage.

Assignment for a Belgian ice cream company.

Location: Beltman Compressor Techniek workshop

—–

Replacement of an overhauled Howden WRV255/1.65 to replace a WRV255/2.20 screw compressor. The WRV255/2.20 was totally destroyed due to thrust bearing damage, and the WRV255/1.65 is going to be installed to run on both low and high stages, which was not possible to this moment due to excessive rotorlength of the 2.20. Assignment also includes extra spares, like oil filters, and start-up at the Atuneros del Sur tuna factory in Dakhla, Morocco. This compressor replacement is part of a major overhaul project of all 3 Howden screw compressors, including delivery of all spares needed for this maintenance.

 

Location: Beltman Compressor Techniek workshop and Atuneros del Sur Tuna factory in Dakhla, Morocco

—–

Overhaul of a screwcompressor SAB128HR after severe rotordamage. A new rotorpair was placed and the compressor has been installed again, started up after alignment. Assignment for Cooling Service Holland.

 

Location: Beltman Compressor Techniek workshop

—–

Emergency overhaul of a Grasso M-3 screw compressor after severe damage. Rotors were stuck in the compressor body, Male rotor was bended, suction and discharge facings were damaged: serious restoring was needed. After mounting of new Axial bearings and a new main drive coupling, the compressor has been started up again on the Aracari Arrow Juice Vessel.

Location: workshop Beltman Compressor Techniek/Aracari Arrow, Emden (D) – Vlissingen (NL)

——

Bearing and slide valve inspection of a Howden screw compressor WRVi255 at an oil field in Kazahkstan. Also alignment chech has been done.

Location: Kalamkas Oil Field, Kazahkstan

——

Replacement of the motor bearings on a Howden WRV255 screw compressor unit.

Location: Friesland, The Netherlands


——

Complete overhaul of a Howden screw compressor MK5/XRV204. The compressor is part of a twin compressor unit, and has been dismantled after running over 32.000 hours. After the overhaul the compressor is aligned cold/hot and started up again. Also the 7 coalescer elements and the lubrication oil filters have been replaced.

 

Location: workshop Beltman Compressor Techniek/Bad Bentheim, Germany

—–


Start up of a new Howden MK5/WCVHS255 and complete overhaul of a Howden screw compressor MK5/WRVHS255 on a Polypropylene plant in Thailand. The new compressor replaces the old one, which is overhauled and provided with a new set of rotors.

 

Location: HMC Polymers Rayong, Thailand

—–

Start up of 2 off complete overhauled Howden screw compressors Mk6/WRV204/14550 on a shrimps trawler. Both compressors are equipped with temperature controlled oil injection valves to maintain constant discharge temperature, as the compressors are running on frequency drive from now on (1800-4000rpm) and the capacity slide valves are fixed at maximum. Assignment for Johnson Controls Marine Denmark.

Location: Sivulliq Frederikshavn, Denmark

—–

Bearing and slide valve inspection of a screw compressor Howden Mk6/WRViN321/220 at a site in Valencia.

Location: Valencia, Spain

—–

Complete overhaul of 3 off Howden screw compressors on site at the PTTEP-S1 oil refinery plant in Thailand. The two WCV321 and one WCV255, running on Propane, are completely dismantled, measured, cleaned and provided with new Original Howden spare parts. The compressors have been leak tested and started. Concerns an assignment from SES International (Circor).

Location: PTTEP-S1 plant Thailand


—–

Bearing inspection of 2 stuks Howden screw compressors, WRV321 en WRV204. Compressors are opened and bearings and slide valves are checked on wear. The bearings of the WRV204 are replaced by new ones.

 

Location: Herste, Germany

—–

Complete overhaul of a Howden screw compressor Mk2/XRV163 after several shaft seal damages. The labyrinth will be machined to fit properly and prevent the shaft seal from hammering. Compressor from Johnson Controls Marine, Denmark.

 

Location: workshop Beltman Compressor Techniek

—–

Complete overhaul of 2 Howden screw compressors Mk6/WRV204. All bearings and seals have been changed, also the rotors are checked on clearances and straightness. The slide valves have been fixed in maximum position as they will run on VSD from now on. Temperature controlled injection valves are mounted in the main oil injection line, to prevent the compressor from running with excessive amounts of oil in the lower speed range. The compressors are returned to Sivulliq shrimps trawler, as part of a major overhaul by Johnson Controls Marine, Denmark.

 

Location: workshop Beltman Compressor Techniek

—–

Bearing, slide valve and rotor inspection of 2 off screw compressors Howden Mk5/WRV255/13050. On 1 compressor the axial bearings are replaced by a new set of bearings after excessive axial clearance. Also shaft seal change on 1 of the Viking oil pumps after serious leakage. Both units are started and tested.

   

Location: Eurofrigo Coldstores Maasvlakte Rotterdam, The Netherlands

—–

Complete overhaul on site in Thailand of a Howden Mk4D/WRV255 screw compressor, running on Propane, from 1989. It concerns the first of four compressors: next three follow up end of March. This screw has had only few maintanance in the last years, and is completely overhauled now. The capacity spindle is modified after damage of the o-ring journal. The runway of the slide has severe damage and has been welded/milled.

   

Location: workshop PTTEP-S1 site (oil/LPG plant), Thailand

—–

Complete overhaul on site in Norway of a Howden Mk6/WRVi255 screwcompressor, running on ammonia. All seals, axial bearings and shaft seal have been changed.

 

Location: workshop MMC Tromsø, Norway

—–

Complete overhaul of a SAB163HR screwcompressor after severe axial bearing damage. The Male rotor has damaged the suction cover, the cover and the rotorset have been replaced. After the overhaul, the compressor is re-installed, aligned cold/hot and started at Coldstores in Barendrecht, The Netherlands. Concerns an assignment from Cooling Service Holland, Oosterwolde, The Netherlands.

  

Location: workshop Beltman Compressor Techniek

—–

Delivery and installation of a new bare shaft Howden XRV163/193 screwcompressor on a shrimps trawler in Greenland. Old compressor is taken of, new one installed, aligned cold/hot and started/tested. Concerns an assignment for Johnson Controls Marine, Denmark.

 

Location: Polar Nataarnaq in Nuuk, Greenland

—–

Complete overhaul of 2  Viking oil pumps. It concerns 1 off AK4195 and 1 off AL4195. The pumps will run with our own brand new Antimone Carbon shaft seal.

Location: workshop Beltman Compressor Techniek

——

Bearing, slide valve and rotor inspection of 2 Howden screw compressors. Concerns 1 off WRV321 and 1 off WRV204, from which the axial bearings have been changed. Also the shaft seal of both compressors have been changed.

 

Location: Bavaria, Germany

—–

Inspection and overhaul of a cast steel Howden screw compressor. It is a WCVS204 and a special design, used for other than the regular cooling gases. The compressor is provided with Fluorsilicon o-rings abd a double Nitrogen controlled shaft seal. Assignment from SES International in Delden, The Netherlands.

 

Location: workshop Beltman Compressor Techniek

—–

Complete overhaul of a Sabroe SAB128HR after serious axial bearing damage, caused by current flow from the E-motor through the compressor. The rotorset is replaced by a new one, the suction cover is restored. After the overhaul the compressor is re-installed and started/tested, and of course, aligned cold/hot at the Bakker Coldstores site in Barendrecht, The Netherlands. Assignment from Cooling Service Holland, Oosterwolde, The Netherlands.

 

Location: workshop Beltman Compressor Techniek

—–


Axial bearing inspection of 2 off Howden WRV255 and 3 off Grasso GSL compressors.

Location: Friesland, The Netherlands

—–

 

Exchange of 5 off shaft seals and maintenance on Howden screw compressors XRV204 compressors after several serious damages.

Location: Coldstore Bahrein

—–

Commissioning of a condensing unit equipped with 2 Howden WRVi255 compressors. The unit is used for cooling/condensing to liquid of a nh3 tank and is completely Ex.

Location: Körfez, Turkey

—–

Commissioning of a screw compressor unit Howden WRVi321. This compressor is provided with 2 oil pumps, running on nh3 and completely designed in Ex.

   

Location: Yara Porsgrunn, Norway


—–

Inspection of a Sabroe screw compressor SAB202. Bearings and slide valve are checked on wear, the shaft seal has been exchanged after excessive leakage.

 

Location: Beerse, Belgium

—–

Inspection of 2 off Howden WRV204 screw compressors on a shrimps trawler in Frederikshavn. During maintanance of the trawler the compressor bearings and slide valves are checked on wear, both shaft seals have been exchanged.

 

Location: Frederikshavn, Denmark

—–

Complete overhaul of 2 off Howden WRV321 screw compressor units. The compressors and oil pumps are overhauled and the units are checked: all filters have replaced/cleaned.

Location: Valencia, Spain

—–

Commissioning of a Howden WCV163 compressor on a LPG plant. The compressor unit is built locally by Howden Beijing. The commissioning was under supervision of and in collaboration with Howden Hua and concerns testing, looptesting, alignment check and leaktesting.

 

Location: Yinchuan, China

—–

Bearing inspection of 2 stuks Howden screw compressors, WRV321 en WRV204. Compressors are opened and bearings and slide valves are checked on wear. The bearings of the WRV204 are replaced by new ones.

 

Location: Herste, Germany

—–

Bearing inspection of a Mycom VMD250 and a Howden WRV204. The axial bearings and the slide valve of the Howden are checked on wear.

Location: Sögel, Germany

—–

Bearing inspection and restoration of the slide valve (oversized guide block) of a Howden MK6/WRV204 screw compressor.

Location: Oostende, Begium

—–

Bearing inspection and slide valve inspection of 2 off MAN-GHH255-G screw compressors from years 1971 en 1973. Journal bearing clearance is measured and the axial bearings of 1 compressors have been replaced. Also the capacity switches and the potentiometer are replaced by a LPI (Local Position Indicator 4-20mA).

   

Location: Solvay Chemicals-Bad Hönningen, Germany

—–

Exchange of a Sabroe screw compressor SAB163 and a Hitachi electric motor, with laser alignment and start up.

     

Location: ACT Coldstores-Bucurest, Romania

———–

Complete inspection of 3 off Howden WRV255 screw compressors. The 3 compressors have been dismantled completely and provided with new gaskets.

    

Location: workshop Beltman Compressor Techniek